Here is how to return your IR-2 to its factory settings.
https://static.roland.com/manuals/ir-2/eng/125862015.html
- Turn off the power by disconnecting the cable from the INPUT A (MONO) jack.
- Set the type knob to "BROWN".
-
Turn the other knobs, besides the type knob, all the way counterclockwise.
You should have the controls set like this. -
While holding down the pedal switch, turn on the power by inserting your cable into the INPUT A (MONO) jack.
Keep pressing the pedal switch until the CHECK indicator slowly blinks orange. Once the CHECK indicator starts blinking rapidly, release the pedal switch. -
Press the pedal switch.
The CHECK indicator should now rapidly blink orange.
Once the CHECK indicator lights up orange continuously, the IR-2 is restored to its factory settings. - Turn off the power by disconnecting the cable from the INPUT A (MONO) jack.