Performance and Patch data on the JV-80, JV-90, and JV-1000 can be recorded into your MIDI sequencer by performing a system exclusive bulk dump. Make sure that the MIDI OUT port on your keyboard is connected to the MIDI IN port on your sequencer or MIDI interface. Use the following procedure to record a system exclusive bulk dump:
- Press WRITE
- Cursor to [BULK] and press ENTER.
- Select [Internal, Card or Temporary] and press ENTER
- Select [Performance, Patch, Rhythm, or All].
- Make sure that your sequencer is set to record system exclusive messages and begin recording.
- Press ENTER.
NOTE: The display will indicate when the bulk dump is finished (depending on the amount of data sent, it can take as many as 20 measures of a song recording in 4/4 time at a tempo of 120 beats per minute to store the data.
Owner's Manual: https://www.roland.com/us/support/manual_archive/