The JV-30 does not actually store User Tones in a location that can be addressed by a simple program change message. Instead, it transmits the settings for Attack, Decay, Release, Resonance, Freq. Cutoff, LFO Rate, LFO Delay, and LFO Depth each time you access a User Tone from the front panel.
This information can be recorded in your sequencer so that during playback these parameters can be automatically recalled. Make sure that your sequencer is setup to record Continuous Controller (CC) messages.
Use the following procedure to record this information into your song:
- Put your sequencer into record mode.
- With your sequencer recording, select the desired User Tone by pressing the corresponding Bank and Number buttons on the JV-30.
- Stop your sequencer.
To confirm that the information has been recorded, check the Event List on your sequencer or a Micro editing page. These messages are Non Registered Parameter Numbers (NRPN) and will be represented by continuous controller numbers 98, 99, and 6.
Owner's Manual: https://www.roland.com/us/support/manual_archive/