Use the following steps to calibrate the on-board EXP pedal on the GT-10 or GT-10B:
1. Press SYSTEM.
2. Press cursor (>) right to select PEDAL CALIBRATION.
3. Press CATEGORY/ENTER.
4. Heel back on the EXP pedal until it stops.
5. Press CATEGORY/ENTER.
6. Press the EXP all the way toe-forward.
7. Press CATEGORY/ENTER.
8. Turn the VALUE dial to set the desired threshold for the toe-end switch (1-16). A lower value allows for the switch to be activated with minimal pressure. More force is needed for higher values.
9. Press EXIT when you're finished.