The following is helpful troubleshooting and setup information for the VH-10 Hihat:
First, check and confirm that you have the cables connected correctly.
- The cable labeled "HHC" on the harness should be connected to the VH-10's Motion Sensor.
- The cable labeled "HH" should be connected to the TRIGGER OUT jack on the bottom of the VH-10 pad.
While in the calibration menu in the TD-17 (SETUP > HiHat Settings > ENTER), remove the VH-10's top pad and use your fingers to push the cylinder spring-loaded mechanism on the motion sensor up and down manually. When doing this you will [should] see the indicator moving up and down between the two vertical bars in the TD-17's display.
If so, check the hihat clutch assembly on the underside of the VH-10 pad and make sure it is making contact with this piece when you place the pad back on the hihat stand.
Next, calibrate the VH-10 by following the Steps in this link:
Note: It's possible that you may have the motion sensor mounted upside down on the hihat stand. Make sure the black spring-loaded center piece on the motion sensor is facing upwards while mounted on the hihat stand.